BMC-S30
SET

EFFECTIVE WAY TO GET BMC

The BMC-S30 Set, developed through accumulated
expertise in cell therapy over a ling period of time,
enables one-step extraction of bone marrow concentrate.

Moreover, it enables more accurate and safer operations
by allowing you to extract bone marrow concentrate
without any contamination within no time.

What is Bone Marrow Concentrate?

It is a concentrated substance extracted after centrifuging bone marrow harvested
from the upper pelvic bone. It consists of bone marrow stem cells and
growth factors effective for tearing arthritis.

BMC-S30 SET
EFFECTIVE WAY TO GET BMC

01. Proven by Research Studies

· Clinical Trials done in Europe using proprietary products

02. Extraordinary Quality

· Manufactured and sourced in PRP specializing company

· KGMP, KFDA

03. Effective and Efficient Bone Marrow Concentrate separation

· Bone Marrow Aspirate Concentrate isolation within 5 min

· Adjustable dosage with ease, depending on the usage environment

Total Cell from
Bone Marrow Anaylisis

EGF(Epidermal Growth Factor) : Cell Proliferation Stimulation, Promotion of Skin Graft Wound Healing

Tested Agency: Medical School of Chosun University | Device Used: BD FACSymphony A5 Laser, 28 color Analyzer

Bone Marrow

BMC-S30

1
16.4
  • 0

  • 2

  • 4

  • 6

  • 8

  • 10

  • 12

  • 14

  • 16

CD24(+) (Stem Cell Labeling Factor) : Produce all blood cells

Tested Agency: Medical School of Chosun University | Device Used: BD FACSymphony A5 Laser, 28 color Analyzer

Bone Marrow

BMC-S30

1
5.82
  • 0

  • 2

  • 4

  • 6

  • 8

  • 10

  • 12

  • 14

  • 16

TNC (Total Nucleated Cells) : A cell with red blood cells removed

Tested Agency: Medical School of Chosun University | Device Used: BD FACSymphony A5 Laser, 28 color Analyzer

Bone Marrow

BMC-S30

1
4.345
  • 0

  • 2

  • 4

  • 6

  • 8

  • 10

  • 12

  • 14

  • 16

TGF-B1(Cellular Functional Dermal Protein) : Promote wound healing, proliferate epithelial and intravascular cells

Tested Agency: Medical School of Chosun University | Device Used: BD FACSymphony A5 Laser, 28 color Analyzer

Bone Marrow

BMC-S30

1
2.595
  • 0

  • 2

  • 4

  • 6

  • 8

  • 10

  • 12

  • 14

  • 16

VEGF (Vascular Endothelial Growth Factor) : Proliferative endothelial cells, neovascularization

Tested Agency: Medical School of Chosun University | Device Used: BD FACSymphony A5 Laser, 28 color Analyzer

Bone Marrow

BMC-S30

1
1.7
  • 0

  • 2

  • 4

  • 6

  • 8

  • 10

  • 12

  • 14

  • 16

EGF
CD34(+)
TNC
TGF-β1
VEGF

BMC-S30 | A Bone Marrow Biopsy Needle | 10cc Syringe | 30cc Syringe | 18g sterilized needle | 21g sterilized long needle

BMC-S30 SET
User Guide

EFFECTIVE WAY TO GET BMC

01

Extraction: Extract bone marrow using bone marrow biopsy needle and two 30cc syringes.
(total of 50cc)

02

Bone Marrow Injection: Inject the bone marrow slowly through the outer injection lid.

03

Securing Space of Red Blood Cell: Rotate the bottom handle cap clockwise until the silicone reaches a little bit lower than 15 labeled on the tube.

04

Centrifuge: Place two BMC-S30 proportionally into the dedicated centrifuge, and adjust the setting of the centrifuge.
(3,000rpm / 5 min)

05

Repeat: Repeat the process for the remaining 30cc.

06

Position Bone Marrow Concentrate: Rotate the bottom handle cap to position the Red Blood Cell threshold, and enclose the upper cap.

07

Injection Syringe Connector Coupling: Insert the injection syringe connector into the central extraction port until fully inserted, and attach a 10cc syringe.

08

Bone Marrow Concetrate Extraction: Rotate the bottom handle cap counter-clock-wise to extract the bone marrow concetrate through the syringe.

09

Repeat: Repeat the process for the remaining 30cc.

10

Replace the Needle: Replace the needle to 18g needle for operation.

BMC-S30 SET
User Guide

EFFECTIVE WAY TO GET BMC